Integrated microgrid systems

One equipment platform for solar, storage, diesel and critical loads.

Coordinate generation and backup in a single architecture. HONKILO offers compact solar-storage-diesel cabinets, commercial microgrid systems and containerized energy blocks with integrated PCS, BMS, EMS and solar input options.

Cabinet capacity48-522 kWhCompact to high-power cabinets
Container capacity1-20 MWhScalable project architecture
Power range25 kW-10 MWCabinet and container formats
Mode switchingUnder 10 msGrid and off-grid transition

System architecture

Four energy sources. One operating strategy.

PV, battery storage, diesel generation and the utility grid can be coordinated around load priority and site conditions.

Solar PVMPPT input and generation
BatteryStorage, smoothing and backup
Diesel backupGenerator interface and control
PCS / combinerPower conversion and switching
Loads & gridPriority loads and interconnection
HONKILO
Integrated microgrid cabinet

Solar-storage-diesel cabinet

Compact integration for sites with limited space.

A single cabinet can combine battery, BMS, PCS, EMS, MPPT and a diesel-generator interface. Cabinet formats suit commercial facilities, telecom sites, rural loads, resorts and distributed energy projects.

25 to 250 kW power blocks
48 to 522 kWh battery capacity
Solar and utility charging
Diesel generator interface
Parallel multiple cabinets
Air- or liquid-cooled options
Define a microgrid cabinet

System families

Match integration depth to project scale.

Cabinet systems simplify distributed projects. Container systems create a repeatable energy block for larger facilities and utility applications.

01

Compact microgrid

48-241 kWh cabinets

Integrated equipment for small commercial, rural, telecom and island loads. Configurations can support AC single- or three-phase architectures.

25-125 kWIP20 / IP54Diesel-ready
View representative ranges
02

High-power cabinet

261-522 kWh systems

Liquid-cooled cabinets combine larger battery capacity with 125 or 250 kW conversion for commercial facilities and microgrid backbones.

125-250 kWIP65 batteryUp to 12 parallel
Explore configuration options
03

Container systems

1-20 MWh energy blocks

10-ft and 20-ft containers can integrate battery, PCS, EMS and solar/diesel interfaces, with 690 / 800 Vac and medium-voltage options.

0.5-10 MWAC / DC coupling11 / 35 kV options
Compare storage platforms
04

Power conversion

PCS & combiner cabinets

Standalone 500 and 750 kW conversion equipment supports broad DC input windows, multi-input solar operation and grid/off-grid switching.

500 / 750 kWUp to 950 Vdc4-6 inputs
See PCS specifications

Representative product matrix

Plan capacity, power and integration in one view.

These ranges show the equipment families available for configuration review. Final ratings, grid codes, certifications and interfaces are confirmed per destination.

Microgrid, PCS and combiner equipment

Configuration review required
Product familyBattery energyPower / currentIntegrationTypical format
Compact microgrid cabinet48-241 kWh25-125 kWBattery + BMS + PCS + EMS + MPPT + diesel interfaceIP20 / IP54 cabinet
High-power microgrid cabinet261-522 kWh125-250 kWLiquid-cooled battery with integrated conversionOutdoor cabinet, up to 12 parallel
10-ft container0.52-1 MWh250-500 kWIntegrated PCS, EMS and solar/diesel optionsAC or DC coupled
20-ft container1-2 MWh0.5-1 MWSolar-storage-diesel microgrid platformLiquid- or air-cooled
Large energy block2.5-20 MWh1.25-10 MWBattery, PCS and medium-voltage transformer options690 / 800 Vac; 11 / 35 kV
PCS cabinetBattery 680-950 Vdc500 kWMulti-MPPT and transformer variantsStandalone cabinet
Combiner cabinetPV, grid, diesel and load inputs500 / 750 kW4-in-1 or 6-in-1 energy routingIP54 cabinet

Parallel capacity, transition time, transformer inclusion, AC voltage and export packaging depend on the selected system. HONKILO will confirm the final bill of materials after reviewing the single-line architecture.

Project fit

For sites where conventional grid service is not enough.

A microgrid can reduce fuel use, improve power reliability and create a clear path for adding renewable capacity.

Remote communities
Industrial facilities
Commercial campuses
Telecom & critical sites
Resorts & islands
Charging hubs

Engineering priorities

Know the site before fixing the equipment.

Microgrid performance depends on load behavior, generator compatibility, grid quality, solar resource and the required level of resilience.

Load priorityDefine critical, controllable and non-essential loads.
Generation mixSet solar, storage and diesel roles clearly.
Operating modesReview grid-tied, islanded and transition requirements.
Expansion pathPlan additional capacity without redesigning the control layer.

Start with your site

Turn a difficult energy site into a defined architecture.

Share the load profile, available generation and reliability target to begin a microgrid configuration review.